{"id":1528,"date":"2017-05-08T16:00:05","date_gmt":"2017-05-08T15:00:05","guid":{"rendered":"https:\/\/www.chatteris.biz\/blog\/?p=1528"},"modified":"2022-04-06T13:46:34","modified_gmt":"2022-04-06T12:46:34","slug":"voltage-control-relay","status":"publish","type":"post","link":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/","title":{"rendered":"Voltage Control Relay"},"content":{"rendered":"<p>Link back to Radio Mast Automation &#8211; <a href=\"\/\/www.chatteris.biz\/blog\/mast-controller-wiring\/\">HERE<\/a>&nbsp;where the EASY RL-V23 unit can just be seen attached to the lid of the mast controller.<\/p>\n<figure id=\"attachment_1529\" aria-describedby=\"caption-attachment-1529\" style=\"width: 3264px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1529 size-full\" src=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg\" alt=\"Voltage Unit\" width=\"3264\" height=\"2448\" srcset=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg 3264w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333-300x225.jpg 300w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333-768x576.jpg 768w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333-1024x768.jpg 1024w\" sizes=\"auto, (max-width: 3264px) 100vw, 3264px\" \/><\/a><figcaption id=\"caption-attachment-1529\" class=\"wp-caption-text\">EASY Voltage Unit<\/figcaption><\/figure>\n<p>The above module was from eBay and advertised as a &#8217;12V Voltage Control \/Delay Switch \/OverVoltage \/Under Voltage Protection Module&#8217; for \u00a34.92.<\/p>\n<p>This unit is incredibly versatile, and I&#8217;ve included the operating instructions in the blog.<\/p>\n<p>I have used this module to monitor the charging voltage of a battery, once the voltage has reached a pre-set value, an output will trigger to stop the charger.<\/p>\n<p><a href=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Drawing1.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1535 size-full\" src=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Drawing1.jpg\" alt=\"voltage relay\" width=\"723\" height=\"768\" srcset=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Drawing1.jpg 723w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Drawing1-282x300.jpg 282w\" sizes=\"auto, (max-width: 723px) 100vw, 723px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Operating modes:<br \/>\nP-1: Timer ( 1-999 S \/ 1-999 Min)<br \/>\nP-2: Delay timer ( 1-999 S \/ 1-999 Min)<br \/>\nP-3: Voltage control relay ( control the load on\/off)<br \/>\nP-4: Voltage control Timer- A (release first)<br \/>\nP-5: Voltage control Timer- B (close first)<br \/>\nP-6: Voltage range control relay<br \/>\nP-7: Voltage range control Timer<br \/>\nP-8: Set display off<br \/>\nTiming Range: 0-999 seconds or 0-999 minutes (0.1s-999s optional)<br \/>\nVoltmeter display range: DC 0-99.9 V<br \/>\nVoltage detection error: \u00b1 0.1V<br \/>\nOperating Power: DC10~16V (5V,24V optional)<br \/>\nRelay parameters:<br \/>\nCoil Voltage: DC 12V (5V,24V optional)<br \/>\nA set of conversion (normally open and normally closed)<br \/>\nContact load: 10A\/277V AC or 10A\/30V DC<br \/>\nContact resistance: \u2264 100m\u03a9 (1A 6VDC)<br \/>\nMechanical durability: 10 millions<br \/>\nElectricity durability: &gt; 100,000 (10A-250VAC)<br \/>\nOperating Temperature: -40 ~ 85\u2103<br \/>\nExternal signal input: (5~ 12V) or passive switch (9 levels delay time can be set)<br \/>\nTimer mode can set the relay contact close and release time, the implementation of a single timing loop<br \/>\nIn voltage control mode, can preset upper and lower voltage values limits<br \/>\nSet display shut, the minimum current values are 6mA\/12V (delay released)<br \/>\nThe pre-set parameters can be saved after power off.<br \/>\n2 Operating modes:<\/p>\n<p>Connect to power, LED digital tube displays words &#8220;E-A-Z-Y-t\u201d in turn, system enter into the selection state, the initial mode selection is displayed as &#8220;P-0&#8221;, press the \u201cSET\u201d button to select &#8220;P-1~P-8&#8221; mode, press \u201cENTER\u201d to enter the corresponding mode.while any mode running, press the \u201cENTER\u201d button for 3 seconds, system will return to the mode selection state.<\/p>\n<p>Press the \u201cSET\u201d and \u201cENTER\u201d button to connect the power, the controller will be restored to factory settings.<\/p>\n<p>2.1 Timer mode (P-1)<\/p>\n<p>Press the \u201cSET\u201d button to select &#8220;P-1&#8221;, controller system will enter into the timer mode.<\/p>\n<p>\u201cP-1\u201d\/ \u201cP-2\u201d: 1-999 seconds \/minute can be set.<\/p>\n<p>Cyclic run:<\/p>\n<p>In the timer mode, the user can set the relay\u2019s close time T1 and the release time T2,such as setting T1 for 3 seconds, T2 for 7 seconds, the relay will be closed for three seconds then release for 7 seconds, cyclic run.<\/p>\n<p>User also can set cyclic times.<\/p>\n<p>When you have set the values of the T1 and T2 , the system saved the settings, the next time system will be loaded automatically T1 time to wait running.<\/p>\n<p>Timer:<\/p>\n<p>If you set T1 with a specified time, set T2 (release time) with 0, the relay will stop after the timer run T1 time, no longer running, it can be used as a timer, with running time end, the normally open contact of relay release, then press the \u201cENTER\u201d button, the system re-start the timer for T1 time.<\/p>\n<p>In timer state, you can use external switch or pulse signal input Interface on controller to start the timer (trigger).<\/p>\n<p>Timer setting steps:<br \/>\n1) For the first time of set , select &#8220;P-1\u201d time relay mode, LED digital tube display&#8221; 000 &#8220;;<\/p>\n<p>2) Press the \u201cSET\u201d button, system will enter into the T1 time values settings first, the digital LED that wait for set flashing with 1Hz frequency, press \u201cENTER\u201d to select the number of values, press the \u201cSET\u201d button for three times to enter the T2 time values settings, and cyclic times, press the \u201cSET\u201d button to exit the set state, the system waits to press \u201cENTER\u201d button to start running.<br \/>\n3) In the time setting state ,time values\u2019 unit can be switched to minutes unit or second unit, press the \u201cSET\u201d button to enter the time set by state (set LED digital tube flashing) ,at this time Press the \u201cSET\u201d button for 3 seconds to release ,the LED digital tube will light the right decimal points, it means that timing values with minutes unit, if the decimal point dose not light, it means that timing values with seconds unit.<br \/>\n4) After setting is completed, press the \u201cSET\u201d button to exit the setting state, press \u201cENTER\u201d to start timing, if timing values is set with second unit, seconds values will display with countdown form. If timing values is set with minute unit, the right decimal point flashing with 1Hz frequency, means the countdown is running. While timer is running, the normally open contact of relay connected, the normally closed contact of relay disconnect, press the \u201cENTER\u201d to halt run, press the \u201cENTER\u201d for three seconds to return mode selection state \u201cP-0\u201d.<br \/>\n2.2 Delay timer (P-2)<\/p>\n<p>The Setting method of \u201cP- 2\u201d is the same as \u201cP- 1\u201d, in the mode of \u201cP-2\u201d, the relay will first execute release of T1 time then closed with T2 time.<\/p>\n<p>2.3 Voltage control relay mode (P-3)<\/p>\n<p>In mode selection state(\u201cP-0\u201d), press the \u201cSET\u201d button to select &#8220;P-3&#8221;, then press the \u201cENTER\u201d to enter the voltage comparison control mode, the controller will detect voltage from \u201cVOL\u201d Interface and display values (DC 0-99.9V),it also can be used as a DC voltmeter ,the default initial run state relay contact is closed (normally closed contact is disconnected, normally open switch on), press the \u201cSET \u201cbutton to set the three bit values, the LED digital tube is set to flashing with1Hz frequency, first to be set upper limit voltage values , press the \u201cSET\u201d button three times, lower limit values of voltage to be set,press the \u201cENTER\u201d button to increase the number of values, the lower limit voltage can not exceeds the upper limit, press the \u201cSET\u201d button to make digital tube is no longer flashing, this time system enter into voltage control mode , the controller detects DC voltage from external input Interface , when voltage detection exceed the upper limit of the pre-set, the relay close (normally open contact connect ,normally closed disconnect), until the voltage drops below the lower limit pre-set, the relay will release (normally closed contact connect , normally open contact disconnect).<\/p>\n<p>In voltage control condition, press the \u201cSET\u201d button for three seconds then release the button, the contact of relay state will be reversed. such as: the relay close when detect voltage below the lower limit voltage.<\/p>\n<p>If the pre-set voltage upper and lower limits set to the same, such as 12.0V, when controller detect volts at 12.0 fluctuations may cause the relay contact frequent action, we recommend to set the voltage to maintain the difference between the upper and lower limits.<\/p>\n<p>Note: The detection voltage terminal must connected reliable, have not loose wiring around the circuit board insulation ,may lead to the induced voltage detection values is not accurate.<\/p>\n<p>2.4 Voltage control Timer mode (P-4 \/ P-5)<\/p>\n<p>\u201cP-4\u201d or \u201cP-5\u201d mode is composed of \u201cP-1\u201d and \u201cP-3\u201d or \u201cP-2\u201d and \u201cP-3\u201d.When the system switched to \u201cP-4\u201d from \u201cP-1\u201dor\u201cP-2\u201d,it will enter the voltage control timer mode, the controller will detect voltage from \u201cVOL\u201d Interface ,when detect voltage exceed the upper limit of the pre-set voltage, the timer will start , until the volts drops below the lower limit pre-set , the timer stop.<\/p>\n<p>If you set time in \u201cP-1\u201d mode previous, then enter the \u201cP-4\u201d mode , the relay will close with timer first ,then release, If you set time in \u201cP-2\u201d mode previous, then enter the \u201cP-4\u201d mode ,the relay release with timing then closed.<\/p>\n<p>The difference between \u201cP-4\u201d and \u201cP-5\u201d is the relay\u2019s Initial state, \u201cP-4\u201d mode relay release first, but \u201cP-5\u201d mode relay close first.<\/p>\n<p>Press the button of \u201cSET\u201d last for 3 seconds, the timer will start in the case of the voltage is below the lower limit. the setting method of limit pre-set voltage, please refer to section 2.3.<\/p>\n<p>For example:<\/p>\n<p>(1) In P-2 mode , set T1 005, T2 000, then enter P-4 mode , voltage detection exceed the upper limit of the pre-set the relay will close after 5 seconds, voltage drops below the lower limit pre-set the relay release Immediately.<br \/>\n(2) In P-1 mode , set T1 005, T2 000, then enter P-5 mode, voltage below the lower limit pre-set the relay close immediately, voltage detection exceed the upper limit of the pre-set the relay will release after delay 5 seconds.<br \/>\nVoltage control logic can be reversed with press SET key for 3 seconds.<\/p>\n<p>2.5 Voltage range control relay (P-6)<\/p>\n<p>If the voltage controller detects exceed the upper limit of the pre-set voltage, or the voltage drops below the lower limit pre-set voltage, the relay will close, otherwise the relay release between upper limit and lower limit range. Press the button of \u201cSET\u201d last for 3 seconds, the relay reversed. The relay will close between upper limit and lower limit.<\/p>\n<p>2.6 Voltage range control Timer (P-7)<\/p>\n<p>If the voltage controller detects exceed the upper limit of the pre-set voltage, or the voltage drops below the lower limit pre-set voltage, the relay will run follow time relay mode that has been set in P-1 or P-1 mode previous.<\/p>\n<p>When voltage values between the upper limit and lower limit range, press SET key for 3 seconds, relay reversed between close and release (ON\/OFF).<\/p>\n<p>For example:<\/p>\n<p>In P-1 mode, set T1 005, T2 000, then enter P-7 mode, set relay close between upper limit and lower limit range. When voltage below lower limit or exceed upper limit, the relay will release after 5 seconds.<\/p>\n<p>2.7 Set display shut (P-8)<br \/>\nThe display shows \u201cd-0\u201d means keep bright, you can press the button of \u201cSET\u201d set 0-9 minutes for display shut.<\/p>\n<p><a href=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1538 size-full\" src=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery.jpg\" alt=\"graph\" width=\"1056\" height=\"816\" srcset=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery.jpg 1056w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery-300x232.jpg 300w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery-768x593.jpg 768w, https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/Mast-Battery-1024x791.jpg 1024w\" sizes=\"auto, (max-width: 1056px) 100vw, 1056px\" \/><\/a>Graph showing operation of raise and lower including the automatic charging cycle.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Link back to Radio Mast Automation &#8211; HERE&nbsp;where the EASY RL-V23 unit can just be seen attached to the lid of the mast controller. The above module was from eBay and advertised as a &#8217;12V Voltage Control \/Delay Switch \/OverVoltage \/Under Voltage Protection Module&#8217; for \u00a34.92. This unit is incredibly versatile, and I&#8217;ve included the &hellip; <a href=\"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Voltage Control Relay<\/span> <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[336],"tags":[73],"class_list":["post-1528","post","type-post","status-publish","format-standard","hentry","category-electronics","tag-voltage-relay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Voltage Control Relay - My Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Voltage Control Relay - My Blog\" \/>\n<meta property=\"og:description\" content=\"Link back to Radio Mast Automation &#8211; HERE&nbsp;where the EASY RL-V23 unit can just be seen attached to the lid of the mast controller. The above module was from eBay and advertised as a &#8217;12V Voltage Control \/Delay Switch \/OverVoltage \/Under Voltage Protection Module&#8217; for \u00a34.92. This unit is incredibly versatile, and I&#8217;ve included the &hellip; Continue reading Voltage Control Relay &rarr;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/\" \/>\n<meta property=\"og:site_name\" content=\"My Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/search\/top\/?q=chatterisweather\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/search\/top\/?q=chatterisweather\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-08T15:00:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-06T12:46:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg\" \/>\n<meta name=\"author\" content=\"Ian\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@chatterisdotbiz\" \/>\n<meta name=\"twitter:site\" content=\"@chatterisdotbiz\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ian\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/\"},\"author\":{\"name\":\"Ian\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#\\\/schema\\\/person\\\/8c24a0b1bf9624c7f930fe2f3a5b5f37\"},\"headline\":\"Voltage Control Relay\",\"datePublished\":\"2017-05-08T15:00:05+00:00\",\"dateModified\":\"2022-04-06T12:46:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/\"},\"wordCount\":1614,\"commentCount\":5,\"publisher\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#\\\/schema\\\/person\\\/8c24a0b1bf9624c7f930fe2f3a5b5f37\"},\"image\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/IMG_0333.jpg\",\"keywords\":[\"voltage relay\"],\"articleSection\":[\"Electronics\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/\",\"url\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/\",\"name\":\"Voltage Control Relay - My Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/IMG_0333.jpg\",\"datePublished\":\"2017-05-08T15:00:05+00:00\",\"dateModified\":\"2022-04-06T12:46:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/IMG_0333.jpg\",\"contentUrl\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/IMG_0333.jpg\",\"width\":3264,\"height\":2448,\"caption\":\"EASY Voltage Unit\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/voltage-control-relay\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Voltage Control Relay\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/\",\"name\":\"My Blog of Stuff\",\"description\":\"A blog about stuff that interests me or I have done.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#\\\/schema\\\/person\\\/8c24a0b1bf9624c7f930fe2f3a5b5f37\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/#\\\/schema\\\/person\\\/8c24a0b1bf9624c7f930fe2f3a5b5f37\",\"name\":\"Ian\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/chatteris.jpg\",\"url\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/chatteris.jpg\",\"contentUrl\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/chatteris.jpg\",\"width\":170,\"height\":80,\"caption\":\"Ian\"},\"logo\":{\"@id\":\"https:\\\/\\\/www.chatteris.biz\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/chatteris.jpg\"},\"sameAs\":[\"https:\\\/\\\/www.chatteris.biz\",\"https:\\\/\\\/www.facebook.com\\\/search\\\/top\\\/?q=chatterisweather\",\"https:\\\/\\\/x.com\\\/chatterisdotbiz\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/Chatterisdotbiz\",\"Ian\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Voltage Control Relay - My Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/","og_locale":"en_GB","og_type":"article","og_title":"Voltage Control Relay - My Blog","og_description":"Link back to Radio Mast Automation &#8211; HERE&nbsp;where the EASY RL-V23 unit can just be seen attached to the lid of the mast controller. The above module was from eBay and advertised as a &#8217;12V Voltage Control \/Delay Switch \/OverVoltage \/Under Voltage Protection Module&#8217; for \u00a34.92. This unit is incredibly versatile, and I&#8217;ve included the &hellip; Continue reading Voltage Control Relay &rarr;","og_url":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/","og_site_name":"My Blog","article_publisher":"https:\/\/www.facebook.com\/search\/top\/?q=chatterisweather","article_author":"https:\/\/www.facebook.com\/search\/top\/?q=chatterisweather","article_published_time":"2017-05-08T15:00:05+00:00","article_modified_time":"2022-04-06T12:46:34+00:00","og_image":[{"url":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg","type":"","width":"","height":""}],"author":"Ian","twitter_card":"summary_large_image","twitter_creator":"@chatterisdotbiz","twitter_site":"@chatterisdotbiz","twitter_misc":{"Written by":"Ian","Estimated reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#article","isPartOf":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/"},"author":{"name":"Ian","@id":"https:\/\/www.chatteris.biz\/blog\/#\/schema\/person\/8c24a0b1bf9624c7f930fe2f3a5b5f37"},"headline":"Voltage Control Relay","datePublished":"2017-05-08T15:00:05+00:00","dateModified":"2022-04-06T12:46:34+00:00","mainEntityOfPage":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/"},"wordCount":1614,"commentCount":5,"publisher":{"@id":"https:\/\/www.chatteris.biz\/blog\/#\/schema\/person\/8c24a0b1bf9624c7f930fe2f3a5b5f37"},"image":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#primaryimage"},"thumbnailUrl":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg","keywords":["voltage relay"],"articleSection":["Electronics"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/","url":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/","name":"Voltage Control Relay - My Blog","isPartOf":{"@id":"https:\/\/www.chatteris.biz\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#primaryimage"},"image":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#primaryimage"},"thumbnailUrl":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg","datePublished":"2017-05-08T15:00:05+00:00","dateModified":"2022-04-06T12:46:34+00:00","breadcrumb":{"@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#primaryimage","url":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg","contentUrl":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2017\/05\/IMG_0333.jpg","width":3264,"height":2448,"caption":"EASY Voltage Unit"},{"@type":"BreadcrumbList","@id":"https:\/\/www.chatteris.biz\/blog\/voltage-control-relay\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.chatteris.biz\/blog\/"},{"@type":"ListItem","position":2,"name":"Voltage Control Relay"}]},{"@type":"WebSite","@id":"https:\/\/www.chatteris.biz\/blog\/#website","url":"https:\/\/www.chatteris.biz\/blog\/","name":"My Blog of Stuff","description":"A blog about stuff that interests me or I have done.","publisher":{"@id":"https:\/\/www.chatteris.biz\/blog\/#\/schema\/person\/8c24a0b1bf9624c7f930fe2f3a5b5f37"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.chatteris.biz\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":["Person","Organization"],"@id":"https:\/\/www.chatteris.biz\/blog\/#\/schema\/person\/8c24a0b1bf9624c7f930fe2f3a5b5f37","name":"Ian","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2022\/03\/chatteris.jpg","url":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2022\/03\/chatteris.jpg","contentUrl":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2022\/03\/chatteris.jpg","width":170,"height":80,"caption":"Ian"},"logo":{"@id":"https:\/\/www.chatteris.biz\/blog\/wp-content\/uploads\/2022\/03\/chatteris.jpg"},"sameAs":["https:\/\/www.chatteris.biz","https:\/\/www.facebook.com\/search\/top\/?q=chatterisweather","https:\/\/x.com\/chatterisdotbiz","https:\/\/www.youtube.com\/user\/Chatterisdotbiz","Ian"]}]}},"_links":{"self":[{"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/posts\/1528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/comments?post=1528"}],"version-history":[{"count":8,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/posts\/1528\/revisions"}],"predecessor-version":[{"id":5250,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/posts\/1528\/revisions\/5250"}],"wp:attachment":[{"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/media?parent=1528"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/categories?post=1528"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.chatteris.biz\/blog\/wp-json\/wp\/v2\/tags?post=1528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}